System and scope
1. How do we build an asset inventory for CMMC, and how are assets categorized?
List every system, device, application, cloud service, and person that stores, processes, transmits, or protects CUI, and assign an owner to each. CMMC sorts assets into categories: CUI assets; Security Protection Assets (e.g., firewalls and identity systems); Contractor Risk Managed Assets; Specialized Assets (e.g., operational technology and test equipment); and out-of-scope assets. Each category is assessed differently, so accurate categorization directly lowers assessment cost.
2. How should we document where CUI flows and the boundary around it?
Create a network diagram and a data flow diagram showing how CUI enters your organization, where it is stored and processed, who touches it, and how it leaves. Mark the assessment boundary and every connection that crosses it. Assessors start from these diagrams, so a boundary you can’t show is a boundary they will widen.
3. How do we handle CUI received from the government or primes, including marking?
Identify every contract and channel through which CUI arrives, and route it straight into your controlled environment. Confirm markings with your contracting officer or prime when they are unclear, and mark CUI you create as the contract requires. Train staff to recognize CUI. Unmarked or misdirected CUI is one of the fastest ways to expand your scope.
4. How do we address external service providers such as MSPs and cloud providers?
List every external service provider that stores, processes, or protects CUI or your security systems, and document in your SSP which requirements each one covers. Cloud services handling CUI must meet FedRAMP Moderate or an equivalent standard and include a customer responsibility matrix. An MSP managing in-scope systems is assessed as part of your environment. Keep the contracts and responsibility matrices assessors will ask for.
CMMC controls
People and access
5. How are remote employees and contractors addressed in our CMMC controls?
They are held to the same requirements as on-site staff. Remote access to CUI must go through managed, monitored connections with multi-factor authentication, and CUI should stay inside your controlled environment, for example through a virtual desktop, rather than on personal devices. Alternate work sites need safeguards too. Assessors interview and sample remote workers just like everyone else.
6. What access controls and onboarding and offboarding processes do we need?
Limit access to authorized users with least privilege, approved and recorded before it is granted. Require multi-factor authentication for privileged accounts and for network access by everyone. Screen individuals before granting CUI access, and remove access promptly when people leave or change roles, returning devices and badges. Keep dated records for every step, because assessors sample them.
7. What security awareness training should employees complete?
Everyone with access to CUI systems needs security awareness training at hire and at least annually, covering phishing, handling and marking CUI, reporting incidents, and recognizing insider threat indicators. Staff with security roles need role-based training for their duties. Keep completion records; assessors check them and interview employees to confirm the training stuck.
8. How do we demonstrate that periodic user access reviews are effective?
Review who has access to each in-scope system on a set schedule, commonly quarterly. The system owner confirms each user still needs their access and permissions, and removals are completed and recorded. Keep the reviewed user list, the reviewer’s sign-off and date, and proof that flagged access was removed. A review without follow-up is not effective.
9. How should we manage privileged accounts and service accounts?
Limit administrator access to the few people who need it, use separate admin accounts for privileged work, require multi-factor authentication, and log privileged actions. Assign service accounts an owner, grant minimum permissions, and store secrets in a vault. Review both types in your access reviews. Privileged access is one of the first areas assessors test.
CMMC controls
Operations
10. How should we document incident response and meet DFARS reporting rules?
Write an incident response plan covering detection, analysis, containment, recovery, and user response, and test it at least annually. It must include DFARS 252.204-7012 reporting: report covered cyber incidents to the DoD within 72 hours, which requires a DoD-approved medium assurance certificate, and preserve images of affected systems for 90 days. Record tests and real incidents from start to finish.
11. What vulnerability scanning and penetration testing should we complete?
NIST SP 800-171 requires periodic vulnerability scanning of systems and applications, including when new vulnerabilities are announced, and fixing findings based on risk. Scan at least monthly, and record the results, the fixes, and any accepted risks. Penetration testing is not a Level 2 requirement, but it strengthens your evidence and your security.
12. How do we demonstrate that audit logging and monitoring controls are working?
Collect audit logs from your in-scope systems and security tools in a central place, protect them from tampering, and retain them long enough to support investigations. Synchronize system clocks, review and correlate logs for suspicious activity, and alert on audit logging failures. Then show the reviews happen: review records, tickets for investigated alerts, and escalations.
13. What backup and recovery evidence should we maintain?
Protect the confidentiality of CUI in backups by encrypting them and controlling access to backup storage. Keep your backup schedule, records showing backups succeed, and results of restore tests. While NIST SP 800-171 focuses on protecting backups rather than recovery time, a tested recovery plan protects your contract performance and is expected by many primes.
14. How should we manage configuration and changes to systems?
Establish baseline configurations and an inventory for every in-scope system, apply security settings, and restrict software to what is approved. Track, review, approve, and log changes, and analyze their security impact before deployment. Remove unnecessary programs, ports, and services. Assessors compare your baselines to live systems, so document what you actually run.
CMMC controls
Engineering and protection
15. What encryption does CMMC require, and what does FIPS-validated mean?
When encryption protects the confidentiality of CUI, it must use FIPS-validated cryptography, meaning modules tested and certified under the NIST Cryptographic Module Validation Program. Encrypt CUI in transit and at rest on laptops, mobile devices, removable media, and backups. Using strong but unvalidated encryption is one of the most common NOT MET findings, so check each tool’s validation certificate.
16. What physical security and media protection controls do we need?
Limit physical access to systems and areas holding CUI to authorized people, escort and log visitors, and monitor the facility. Protect CUI on paper and digital media: store it securely, mark it, control who takes it offsite, and sanitize or destroy media before disposal or reuse. Assessors will tour your space and ask to see visitor logs and disposal records.
17. How should we segment our network and protect its boundaries?
Separate systems that handle CUI from the rest of your network, and from any publicly accessible systems, with firewalls or isolated environments. Deny network traffic by default and allow only what is needed, monitor communications at the boundary, and prevent split tunneling on remote connections. Good segmentation is what makes an enclave work and keeps your assessment scope small.